Koel iGreen Offerings
  • AMF as standard
  • KOEL remote Monitoring
  • Silencer inside canopy
  • Aesthetically enhanced genset
  • QR Code enabled genset
  • Multi-colour Status indicator
Features
Low OPEX: Best in class fuel efficiency with O2E technology
Robust and Reliable Product: Lowest maintenance and trouble free product with Kirloskar Engines
Option of Air Cooled and Water Cooled Engines
Compliance: Latest Government Emission Norms CPCB II
Start Type: Controller Based Easy Push Start Type
Customer Service: Quick and affordable door step service coverage (420+ service touch points and 6000+ KOEL trained service professionals on field)
Warranty: 2 years warranty & labour free onsite service under warranty period

KOEL Green is the Genset brand of Kirloskar Oil Engines Ltd (KOEL), the flagship company of the century old Kirloskar Group. KOEL Green is India’s largest selling and most trusted Genset brand for over a decade. Providing back-up power solutions from 15 to 5200 kVA for diverse market sectors, “KOEL Green” has over 1 million Gensets in service across the globe.

Owing to extreme operating conditions in India, preference has been given to robust configurations, that have been running successfully for several years. Also, KOEL is the only manufacturer which provides you with the benefits of choice in terms of Air cooled and Water Cooled gensets.

KOEL Green Gensets offer a unique combination of CPCB norm compliance and enhanced fuel efficiency. Across the range, KOEL Green Gensets offer substan&al savings in fuel cost.

O2E Series (Opmal Operang Efficiency):

Genset ratings are selected based on the present load and future expansion. Fuel efficiency of most Gensets is optimized at the full rating of the Genset.

In practice, Gensets rarely get loaded to full capacity. Power demand varia&tions across day & night, weekdays & weekends.

Summer & winter lead to an average 50-70% loading on the gensets.

Considering this practical situation, KOEL has extended fuel efficiency optimization from 100%, right up to 50% of rated load. Combination of best-in-class fuel efficiency & O2E provides a double advantage.

There is no comfort like being in command. KOEL Green Gensets put the command in your hands. Micro-processor based Genset controllers display a host of Genset parameters and put all controls at your fingertips.

Monitoring Features
  • Lube oil Pressure, Engine Temperature, RPM, lube oil Temperature*
  • Run Hours, No. of starts, Fuel Level, Auto / Manual Stop, BaMery charge condition, AC Phase Voltage, Current, kVA, kW, kWh, kVAr, Power Factor
Optional Features
  • Modbus communica&on*
  • * Features are available from 15 kVA onwards
Diagnostic Features
  • Ballery charging failure, Over speed, Under speed, Over Current, Under Voltage, Over Voltage, Over kW, Phase Sequence monitoring, Phase missing, Common Alarm, Hooter output
  • Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level alarm, Over Crank protection, Routine Maintenance indicator, Genset Test Facility, fail to start/stop

KOEL Green Gensets have always been preferred for their robust design and reliability over long usage life.

KOEL Green range carries the confidence of well-established and proven engine platforms. For compliance to revised CPCB norms, KOEL has carefully selected those technologies which not only retain, but enhance Gensets durability and on-site serviceability.

Thus, KOEL Gensets offer you many years of trouble-free performance; backed by the assurance of prompt support. Peace-of-mind driven by product reliability and low cost of ownership.

KOEL Chhota Chilli Gensets comes with a promise of assured delivery within 7 days of confirm order placement. Genset being a high value capital purchase may lead to needless block of capital and hence need not be purchased in advance. It is prudent to order the genset at the right time and plan the deliveries in line with your readiness to use. This will also avoid damages to genset due to lying unattended at site and engine re-validation cost.

Elementary Points to Ponder during selection of a Genset:

1. Prime rating and Stand-by rating ¹

‘Prime power’ is designed for unlimited hours, as compared to ‘Emergency stand-by&’ designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. KOEL offers Prime power as a standard offer. *Contact KOEL for stand-by ratings.

2. Engine capacity does matter ²

Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance. Higher engine capacity also enables the Genset to respond quickly & positively to sudden load additions.

 

7 Easy steps for a happy Genset Ownership :

  • Insist on a load-study
  • Select the Genset ra&ng as per the load-study and with sufficient margin for future load expansion
  • Apply site-selec&on guidelines carefully
  • Insist on installation in line with KG guidelines
  • Ensure adequate size and proper connec&on of cables
  • Understand the Genset opera&on & maintenance procedures during commissioning
  • Follow routine maintenance protocols through authorized KG service dealers
 

Product Specifications

Prime Rating at rated rpm ( as per ISO8528)1

kVA

40

40

45

62.5

62.5

82.5

100

125

125HD

kW

32

32

36

50

50

60

80

100

100

Genset Model

 

KG1-40AS

KG1-40WS

KG1-45WS

KG1-62.5AS

KG1-62.5AS

KG1-82.5WS

KG1-100WS

KG1-125WS

KG1-125WS HD

Frequency

Hz

50

50

50

50

50

50

50

50

50

Power factor

lagging

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Voltage

V

230 (1Ø) & 415 (3Ø)

415(3Ø)

Governing class (As per ISO 8528 Part-V)

 

G2

G2

G2

G2

G2

G2

G3

G3

G3

Noise level

dBA

< 75

< 75

< 75

< 75

< 75

< 75

< 75

< 75

< 75

Fuel Consumption* 

At 100% Load

Ltrs/hr 

9.9

9.2

10.3

16.2

14.1

18.8

21.9

27.4

27.5

At 75% Load

7.9

7.4

8.7

12.7

11.3

13.8

16.9

20.2

21.4

At 50% Load

5.8

5.5

5.9

8.9

7.5

9.9

12.2

15.3

15.3

Fuel tank capacity

Ltrs

100

100

100

150

150

230

230

230

50

Weight of genset with canopy (approx..)^

Dry

Kg

1270

1250

1250

1700

1420

1710

2040

2090

2520

Wet

Kg

1370

1335

1335

1825

1550

1840

2240

2290

2730

Overall dimensions of genset^

Length

mm

2400

2550

2550

3150

2800

3200

3220

3220

3650

Width

mm

1050

1050

1050

1200

1100

1100

1300

1300

1350

Height

mm

1670

1450

1450

1635

1595

1595

1795

1795

1915

Electrical Battery starting voltage 

Volts-DC

12

12

12

12

12

12

12

12

12

ENGINE

Engine Model

 

HA494TCI G1

3R1040TA G1

3R1040TA G1

HA694TCI G1

4R810TA G1

4R810TA G1

4K1080TA G2

4K1080TA G2

6R1080TA G1

Rated output (Prime Continuous rating as per ISO 8528-1)

KW

41.19

41.2

41.2

61

61

74.8

114.7

114.7

114.7

HP

56

56

56

83

83

102

156

156

175

No. of cylinder

Number

4

3

3

6

4

4

4

4

6

Cubic capacity

Ltrs

3.77

3.12

3.12

5.65

3.24

4.16

4.32

4.32

6.49

Bore x Stroke

mm

100 x 120

105 x 120

105 x 120

105 x 120

100 x 120

96 x 112

105 x 120

105 x 125

105 x 125

Rated Speed

RPM

1500

1500

1500

1500

1500

1500

1500

1500

1500

Aspiration

NA/TC/TA

TC

TA

TA

TC

TA

TA

TA

TA

TC

Lube Oil change period

Hrs

500

500

500

500

500

500

500

500

500

Lube Oil Sump Capacity

Ltrs

8.3

8

8

11

10

10

14

14

18

Coolant Capacity

Ltrs

 

11.5

11.5

 

117.5

24

21

21

28

ALTERNATOR

Insulation Class

 

Class H

Alternator Efficiency (at 100% load) 0.8 pf**

%

89.2

89.2

89.2

91

91

91.4

92

92.5

92.5

Max Voltage Dip at Full Load 0.8 pf Lag

Sec

< 20%

< 16%

< 16%

< 20%

< 20%

< 20%

< 20%

< 20%

< 20%

Max Time to build up rated voltage at Rated RPM

 

< 5 sec provided engine reach the rated speed

< Voltage recovery time 6 sce